Skip to main content
  • Home
  • Dual RG6/U Dual Shield Coax Cable, 500'

Dual RG6/U Dual Shield Coax Cable, 500'

$126.04
SKU: WR2RG6QD05

Order now and we'll ship usually within 1-2 business days.

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

This is a heavy and/or oversized item and does not qualify for our shipping promotion.

Product Description

Description: RG6/U SIAMESE DUAL COAX CATV 18 AWG BC 60% AL BRAID – BLACK – 500 FT RIB

Product Information:

SCP offers a full line of RG6/U BC Coaxial cables. Our RG6/U Dual Shield BC Coax cables are ideal for residential and commercial antenna, cable television and satellite installations.

SCP RG6/U BC Coax cables have an 18 AWG solid bare copper center conductor surrounded by a foam polyethylene dielectric. A bonded aluminum foil and 60 percent aluminum braid provide 100 percent shield coverage.

SCP RG6/U BC Coax cables are swept tested to 3 GHz to ensure performance at applicable frequencies. Each RG6/U Coax cable also has SCP's industry favored Cable Labeling System with sequential foot markings and room/zone/outlet designations.

These SCP RG6/U BC Coax cables are in a Siamese (bonded side by side) configuration. They are UL listed and CM rated.

NOTE: Score with a razor the crease between the cables before splitting the cables apart. Attempting to pull apart without scoring may result in tearing or ripping the cable jacket. Any damage caused to the cable jacket by not scoring is not covered by SCP Warranty.

Available in spools of: 500 Ft.

Tech Specs

  • Part Number: RG6/U-S-BC-BK
  • Standards: UL, CE, RoHS

Construction

  • Center Conductor: Bare Copper
    • Size: 18AWG
    • Diameter (in/mm): 0.0403/1.02
  • Insulate: Skin Foam PE
    • Nom. Thickness(in/mm): 0.070/1.78
    • Insulation Diameter (in/mm): 0.0180/4.57
  • First Shield: Bonded Aluminum Foil
    • Coverage Area: 100 percent
  • First Braid Shield: Aluminum Wire
    • Coverage Area: 60 percent
  • Jacket: Black FR-PVC
    • Nom. Thickness (in/mm): 0.030/0.76
    • Min. Thickness (in/mm): 0.024/0.61
    • Cable Diameter (in/mm): 0.272/6.91

Performance

  • Dielectric Strength: 1 kV/min
  • Impedance: 75 ohms ±3.0 ohms
  • SRL (dB): 5~1000MHz >=20; 1001~3000MHz >=15
  • Capacitance: 16.2 pF/ft
  • DC Loop Resistance: 19.98 ohms/kft at 20°C
  • Velocity Of Propagation: 85 percent

Mechanical Characteristics

  • Test Object: Jacket
  • Before Tensile Strength: 2000 psi
  • Aging Elongation: 200 percent
  • Aging Condition: 100°C / 168 hrs
  • After Tensile Strength: >=85 percent unaged
  • Aging Elongation: >=50 percent unaged
  • Cold Bend Test: -20°C 4 hours; No Cracking
  • Jacket Longitudinal Shrinkage: >=5 percent
  • Center Conductor Break Strength: 85 pounds
  • Operating Temperature Range: -20°C to 75°C