PCS PulseWorx UPB Gateway
Product Description
The PCS Pulseworx Gateway is a Powerline Interface Module that contains an onboard IP web server and a Timed Event Controller. This all-in-one device integrates web-connected IP devices into a UPB network and simplifies configuration of PulseWorx, IP, and other UPB devices.
FEATURES:
- Empowers the use of mobile devices, smart phones and/or tablets to control PulseWorx systems
- Apple iPhone, iPad Mini, iPad applications available
- Microsoft Surface application available
- Supports full line of PulseWorx products
- Android application available Now
- Virtual "Keypads" allow users to trigger keypad buttons remotely
- Mobile applications graphically orientated and optimized for touch/gesture screens
- Enhanced security features
- Username and password protection enforced upon connection.
- Allows up to 8 simultaneous connections
- Individual user level privileges
- Enables remote connection of UPStart to a PulseWorx/UPB system to access and update an installation
- Field updatable firmware
- Built-in astronomical Timed Event Controller with 256 possible events based on 4 schedules
- Scheduling by week or calendar
- Calendar mode appropriate for lite commercial installations
- Complete solution without needing access to a server. Connection are made directly to the Gateway at the installation site
Tech Specs
- Part Number: PGW
Electrical
- Power Requirements: Primary: 120 Volts AC, 50/60Hz
- Transmission Channels: 256 individual timed events over 4 schedules
- Standby Power Consumption: > 0.8 Watts
- Connections/Power Wire: 3-pin grounded outlet
- Network Connection: RJ45 Connector; 100/10 Mbp Ethernet protocol; Adheres to TCP, DHCP and HTTP standards
- TCP Port: 2101
- Telnet Port: 2001
- Secure TCP Port: 2601
- Baud Rate: 4800
- Data Bits: 8
- Parity: None
- Stop Bits: 1
- Flow Control: None
- Environmental Conditions: Indoor Use Only
- Temperature: -40° to 194° F (-40° to 90° C)
- Humidity: 10 to 90 percent RH (non-condensing)
- Certifications: Safety tested for USA and Canada to ETL tested to UL508; UL-508-2010 CSA C22.2 #14-2010
Operation
- UPStart: Must have Version 8.0 Build 1 or higher
- Status LED Modes:
- Blue = Power applied / No message traffic
- Magenta = UPB message received
- Red = UPB message transmitted
- During Power Outage: Retains all settings in non-volatile EERPOM
- Factory Default:
- Tap Program button 5 times, LED will flash BLUE
- Tap Program button 10 times, LED will flash RED
- Tap Program button 2 times, LED will turn BLUE
Mechanical
- Mounting: 3-pin grounded outlet
- Dimensions: 4.0(H) x 2.0(W) 1.25(D) inches
- Weight: 9.6 ounces
- Warranty: 5 Years